Freescale mx25 TS conversion queue module

mx25 touchscreen conversion queue module which controls the ADC unit of the
mx25 for attached touchscreens.

Required properties:
 - compatible: Should be "fsl,imx25-tcq".
 - reg: Memory range of the device.
 - interrupts: Should be the interrupt number associated with this module within
   the tscadc unit (<0>).
 - fsl,wires: Should be '<4>' or '<5>'

Optional properties:
 - fsl,pen-debounce-ns: Pen debounce time in nanoseconds.
 - fsl,pen-threshold: Pen-down threshold for the touchscreen. This is a value
   between 1 and 4096. It is the ratio between the internal reference voltage
   and the measured voltage after the plate was precharged. Resistance between
   plates and therefore the voltage decreases with pressure so that a smaller
   value is equivalent to a higher pressure.
 - fsl,settling-time-ns: Settling time in nanoseconds. The settling time is before
   the actual touch detection to wait for an even charge distribution in the
   plate.

This device includes two conversion queues which can be added as subnodes.
The first queue is for the touchscreen, the second for general purpose ADC.

Example:
	tsc: tcq@50030400 {
		compatible = "fsl,imx25-tcq";
		reg = <0x50030400 0x60>;
		interrupt-parent = <&tscadc>;
		interrupts = <0>;
		fsl,wires = <4>;
	};