What: /sys/bus/iio/devices/iio:deviceX/in_proximity<id>_setup Date: November 2021 KernelVersion: 5.17 Contact: Gwendal Grignou <gwendal@chromium.org> Description: SX9324 has 3 inputs, CS0, CS1 and CS2. Hardware layout defines if the input is + not connected (HZ), + grounded (GD), + connected to an antenna where it can act as a base (DS - data shield), or measured input (MI). The sensor rotates measurement across 4 phases (PH0, PH1, PH2, PH3), where the inputs are configured and then measured. By default, during the first phase, [PH0], CS0 is measured, while CS1 and CS2 are used as shields. `cat in_proximity0_setup` returns "MI,DS,DS". [PH1], CS1 is measured, CS0 and CS2 are shield: `cat in_proximity1_setup` returns "DS,MI,DS". [PH2], CS2 is measured, CS0 and CS1 are shield: `cat in_proximity1_setup` returns "DS,DS,MI". [PH3], CS1 and CS2 are measured (combo mode): `cat in_proximity1_setup` returns "DS,MI,MI". Note, these are the chip default. Hardware layout will most likely dictate different output. The entry is read-only.