What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/control Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one select which data from which profile will be read next. The data has to be 3 bytes long. This file is writeonly. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/profile Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: The mouse can store 5 profiles which can be switched by the press of a button. profile holds index of actual profile. This value is persistent, so its value determines the profile that's active when the device is powered on next time. When written, the device activates the set profile immediately. The data has to be 3 bytes long. The device will reject invalid data. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_primary Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the default of all keys for a specific profile. Profile index is included in written data. The data has to be 125 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_function Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the function of the function keys for a specific profile. Profile index is included in written data. The data has to be 95 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_macro Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the function of the macro keys for a specific profile. Profile index is included in written data. The data has to be 35 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_thumbster Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the function of the thumbster keys for a specific profile. Profile index is included in written data. The data has to be 23 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_extra Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the function of the capslock and function keys for a specific profile. Profile index is included in written data. The data has to be 8 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/keys_easyzone Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the function of the easyzone keys for a specific profile. Profile index is included in written data. The data has to be 294 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/key_mask Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one deactivate certain keys like windows and application keys, to prevent accidental presses. Profile index for which this settings occur is included in written data. The data has to be 6 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/light Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the backlight intensity for a specific profile. Profile index is included in written data. This attribute is only valid for the glow and pro variant. The data has to be 16 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/macro Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one store macros with max 480 keystrokes for a specific button for a specific profile. Button and profile indexes are included in written data. The data has to be 2002 bytes long. Before reading this file, control has to be written to select which profile and key to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/info Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When read, this file returns general data like firmware version. The data is 8 bytes long. This file is readonly. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/reset Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one reset the device. The data has to be 3 bytes long. This file is writeonly. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/talk Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one trigger easyshift functionality from the host. The data has to be 16 bytes long. This file is writeonly. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/light_control Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one switch between stored and custom light settings. This attribute is only valid for the pro variant. The data has to be 8 bytes long. This file is writeonly. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/stored_lights Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set per-key lighting for different layers. This attribute is only valid for the pro variant. The data has to be 1382 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/custom_lights Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set the actual per-key lighting. This attribute is only valid for the pro variant. The data has to be 20 bytes long. This file is writeonly. Users: http://roccat.sourceforge.net What: /sys/bus/usb/devices/<busnum>-<devnum>:<config num>.<interface num>/<hid-bus>:<vendor-id>:<product-id>.<num>/ryos/roccatryos<minor>/light_macro Date: October 2013 Contact: Stefan Achatz <erazor_de@users.sourceforge.net> Description: When written, this file lets one set a light macro that is looped whenever the device gets in dimness mode. This attribute is only valid for the pro variant. The data has to be 2002 bytes long. Before reading this file, control has to be written to select which profile to read. Users: http://roccat.sourceforge.net