        "BriefDescription": "ARITH.FPDIV_ACTIVE",
        "CounterMask": "1",
        "EventCode": "0xb0",
        "EventName": "ARITH.FPDIV_ACTIVE",
        "SampleAfterValue": "1000003",
        "UMask": "0x1"
    },
    {
        "BriefDescription": "Counts all microcode FP assists.",
        "EventCode": "0xc1",
        "EventName": "ASSISTS.FP",
        "PublicDescription": "Counts all microcode Floating Point assists.",
        "SampleAfterValue": "100003",
        "UMask": "0x2"
    },
    {
        "BriefDescription": "ASSISTS.SSE_AVX_MIX",
        "EventCode": "0xc1",
        "EventName": "ASSISTS.SSE_AVX_MIX",
        "SampleAfterValue": "1000003",
        "UMask": "0x10"
    },
    {
        "BriefDescription": "FP_ARITH_DISPATCHED.PORT_0",
        "EventCode": "0xb3",
        "EventName": "FP_ARITH_DISPATCHED.PORT_0",
        "SampleAfterValue": "2000003",
        "UMask": "0x1"
    },
    {
        "BriefDescription": "FP_ARITH_DISPATCHED.PORT_1",
        "EventCode": "0xb3",
        "EventName": "FP_ARITH_DISPATCHED.PORT_1",
        "SampleAfterValue": "2000003",
        "UMask": "0x2"
    },
    {
        "BriefDescription": "FP_ARITH_DISPATCHED.PORT_5",
        "EventCode": "0xb3",
        "EventName": "FP_ARITH_DISPATCHED.PORT_5",
        "SampleAfterValue": "2000003",
        "UMask": "0x4"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational 128-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 2 computation operations, one for each element.  Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_DOUBLE",
        "PublicDescription": "Number of SSE/AVX computational 128-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 2 computation operations, one for each element.  Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x4"
    },
    {
        "BriefDescription": "Number of SSE/AVX computational 128-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 4 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.128B_PACKED_SINGLE",
        "PublicDescription": "Number of SSE/AVX computational 128-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 4 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x8"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational 256-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 4 computation operations, one for each element.  Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_DOUBLE",
        "PublicDescription": "Number of SSE/AVX computational 256-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 4 computation operations, one for each element.  Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x10"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational 256-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 8 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.256B_PACKED_SINGLE",
        "PublicDescription": "Number of SSE/AVX computational 256-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 8 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RCP DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x20"
    },
    {
        "BriefDescription": "Number of SSE/AVX computational 128-bit packed single and 256-bit packed double precision FP instructions retired; some instructions will count twice as noted below.  Each count represents 2 or/and 4 computation operations, 1 for each element.  Applies to SSE* and AVX* packed single precision and packed double precision FP instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.4_FLOPS",
        "PublicDescription": "Number of SSE/AVX computational 128-bit packed single precision and 256-bit packed double precision  floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 2 or/and 4 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point and packed double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX RCP14 RSQRT14 SQRT DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x18"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational 512-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 8 computation operations, one for each element.  Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT14 RCP14 FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.512B_PACKED_DOUBLE",
        "PublicDescription": "Number of SSE/AVX computational 512-bit packed double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 8 computation operations, one for each element.  Applies to SSE* and AVX* packed double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT14 RCP14 FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x40"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational 512-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 16 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT14 RCP14 FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.512B_PACKED_SINGLE",
        "PublicDescription": "Number of SSE/AVX computational 512-bit packed single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 16 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT14 RCP14 FM(N)ADD/SUB. FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x80"
    },
    {
        "BriefDescription": "Number of SSE/AVX computational 256-bit packed single precision and 512-bit packed double precision  FP instructions retired; some instructions will count twice as noted below.  Each count represents 8 computation operations, 1 for each element.  Applies to SSE* and AVX* packed single precision and double precision FP instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RSQRT14 RCP RCP14 DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.8_FLOPS",
        "PublicDescription": "Number of SSE/AVX computational 256-bit packed single precision and 512-bit packed double precision  floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 8 computation operations, one for each element.  Applies to SSE* and AVX* packed single precision and double precision floating-point instructions: ADD SUB HADD HSUB SUBADD MUL DIV MIN MAX SQRT RSQRT RSQRT14 RCP RCP14 DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x60"
    },
    {
        "BriefDescription": "Number of SSE/AVX computational scalar floating-point instructions retired; some instructions will count twice as noted below.  Applies to SSE* and AVX* scalar, double and single precision floating-point: ADD SUB MUL DIV MIN MAX RCP14 RSQRT14 RANGE SQRT DPP FM(N)ADD/SUB.  DPP and FM(N)ADD/SUB instructions count twice as they perform multiple calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.SCALAR",
        "PublicDescription": "Number of SSE/AVX computational scalar single precision and double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 1 computational operation. Applies to SSE* and AVX* scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "1000003",
        "UMask": "0x3"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational scalar double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 1 computational operation. Applies to SSE* and AVX* scalar double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.SCALAR_DOUBLE",
        "PublicDescription": "Number of SSE/AVX computational scalar double precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 1 computational operation. Applies to SSE* and AVX* scalar double precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x1"
    },
    {
        "BriefDescription": "Counts number of SSE/AVX computational scalar single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 1 computational operation. Applies to SSE* and AVX* scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element.",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.SCALAR_SINGLE",
        "PublicDescription": "Number of SSE/AVX computational scalar single precision floating-point instructions retired; some instructions will count twice as noted below.  Each count represents 1 computational operation. Applies to SSE* and AVX* scalar single precision floating-point instructions: ADD SUB MUL DIV MIN MAX SQRT RSQRT RCP FM(N)ADD/SUB.  FM(N)ADD/SUB instructions count twice as they perform 2 calculations per element. The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "100003",
        "UMask": "0x2"
    },
    {
        "BriefDescription": "Number of any Vector retired FP arithmetic instructions",
        "EventCode": "0xc7",
        "EventName": "FP_ARITH_INST_RETIRED.VECTOR",
        "PublicDescription": "Number of any Vector retired FP arithmetic instructions.  The DAZ and FTZ flags in the MXCSR register need to be set when using these events.",
        "SampleAfterValue": "1000003",
        "UMask": "0xfc"
    },
    {
        "BriefDescription": "FP_ARITH_INST_RETIRED2.128B_PACKED_HALF",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.128B_PACKED_HALF",
        "SampleAfterValue": "100003",
        "UMask": "0x4"
    },
    {
        "BriefDescription": "FP_ARITH_INST_RETIRED2.256B_PACKED_HALF",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.256B_PACKED_HALF",
        "SampleAfterValue": "100003",
        "UMask": "0x8"
    },
    {
        "BriefDescription": "FP_ARITH_INST_RETIRED2.512B_PACKED_HALF",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.512B_PACKED_HALF",
        "SampleAfterValue": "100003",
        "UMask": "0x10"
    },
    {
        "BriefDescription": "FP_ARITH_INST_RETIRED2.COMPLEX_SCALAR_HALF",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.COMPLEX_SCALAR_HALF",
        "SampleAfterValue": "100003",
        "UMask": "0x2"
    },
    {
        "BriefDescription": "Number of all Scalar Half-Precision FP arithmetic instructions(1) retired - regular and complex.",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.SCALAR",
        "PublicDescription": "FP_ARITH_INST_RETIRED2.SCALAR",
        "SampleAfterValue": "100003",
        "UMask": "0x3"
    },
    {
        "BriefDescription": "FP_ARITH_INST_RETIRED2.SCALAR_HALF",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.SCALAR_HALF",
        "SampleAfterValue": "100003",
        "UMask": "0x1"
    },
    {
        "BriefDescription": "Number of all Vector (also called packed) Half-Precision FP arithmetic instructions(1) retired.",
        "EventCode": "0xcf",
        "EventName": "FP_ARITH_INST_RETIRED2.VECTOR",
        "PublicDescription": "FP_ARITH_INST_RETIRED2.VECTOR",
        "SampleAfterValue": "100003",
        "UMask": "0x1c"
    }
]